IndustriesOil, Gas & Petrochemical

Hearing Conservation
From Wellhead to Refinery.

Remote rigs, refinery turnarounds, multi-employer sites, and confined spaces. Your operations span hundreds of miles — your HCP needs to cover every worker at every location.

0 dB

Peak rig floor noise

Multi-site

Dispersed operations

Contractors

Turnaround workforce

Dual HPD

Often required

Independent 1910.95 Audit

Independent 1910.95 Audit

Third-Party Reviewed

FDA Registered

FDA Registered

Class II Medical Device

SOC 2 Type II

SOC 2 Type II

AICPA Certified

HIPAA Compliant

HIPAA Compliant

Powered by Vanta

Made in USA

Made in USA

Engineered & Built

The Reality in the Field

Why Traditional Testing Fails in Oil & Gas

Mobile vans can't reach remote wellheads. Clinic visits can't keep up with turnaround contractor onboarding.

Remote Wellhead and Platform Sites

Workers on rigs, wellheads, and offshore platforms are miles from any testing facility. Mobile units can't reach them — and remote workers fall out of the testing cycle entirely.

Turnaround Crews & Contractor Overlap

Refinery turnarounds bring hundreds of contractors for 2–6 weeks. Multi-employer sites create compliance ambiguity: who owns the baseline? Which HCP governs?

Confined Spaces Amplify Noise

Tanks, vessels, and pipe racks create reverberant environments where noise exceeds ambient readings by 10–20 dB. Area monitoring misses these exposures entirely.

Dual Protection Often Required

Many refinery operations exceed 100 dBA, requiring plugs + muffs. If the inner plug fit is poor, the entire dual-protection system fails — but most programs never verify it.

Built for Your Operations

How Soundtrace Fits Into Oil & Gas Operations

Test at Any Remote Location

Any site

field-ready

Soundtrace travels in a case. Set up in a site trailer or tool room. Test rig crews and field operators without travel back to a central facility.

Multi-Employer Compliance

All workers

employees + contractors

Track audiometric testing for both employees and contractors in one system. Verify baseline status before workers enter noise-hazardous areas.

Task-Based Noise Monitoring

Per task

exposure data

Dosimeters capture actual exposure during grinding, sandblasting, and confined-space work — not just ambient area readings.

30-Year Records Across All Sites

30+

year retention

Every audiogram across every wellhead, refinery unit, and platform stored digitally. Workers carry their full audiometric history site-to-site.

Know Your Exposure

Noise Levels Across Oil & Gas Operations

85 dBA OSHA action level
Drilling Rig Floor
Extreme95115 dBA

Rotary table and drawworks

Compressor Stations
Extreme90110 dBA
Fluid Catalytic Cracker (FCC)
Extreme92105 dBA
Turnaround Grinding / Sandblasting
Extreme95115 dBA

Confined-space amplification

Pipe Rack / Pump Areas
Very High85100 dBA
Control Room (near turbines)
High8092 dBA

How Loud Is That?

💬

60 dB

Normal conversation

⚠️

85 dB

OSHA action level

🎸

110 dB

Rock concert

✈️

130 dB

Jet takeoff (300ft)

OSHA ITA Data

Hearing Loss Trends in Oil, Gas & Petrochemical (NAICS 211/324)

OSHA Injury Tracking Application (ITA) hearing loss injury rates per 10,000 workers, by year.

052017201920212023Natl avg
Oil, Gas & Petrochemical (NAICS 211/324)
National Avg

Who We Serve

Types of Companies in Oil, Gas & Petrochemical

Upstream drilling and production with rig crews rotating through remote wellhead sites on 2-week schedules

Midstream pipeline and compressor station operations with small crews at distributed, unmanned sites

Downstream refineries running 1,500–5,000+ workers across multiple process units with periodic turnaround shutdowns

Petrochemical and chemical processing with continuous-process operations and tank farm / loading rack exposure

From Wellhead to Refinery.
Every Worker. Every Site.

See how Soundtrace handles multi-site, multi-employer hearing conservation across upstream, midstream, and downstream.